Dielectric Cooling Fluids for Liquid-Cooled EV Charging Cables
High-power charging pushes several hundred amperes through a cable that still has to be light and flexible. Directly cooled cables rely on a dielectric fluid. This page explains what that fluid has to do – and how we develop it to your specification.
Updated 22 November 2026 · Published by IsoTec
Why charging cables are liquid-cooled
The heat generated in a conductor rises with the square of the current. Without liquid cooling, DC charging cables and connectors reach practical limits at roughly 250 A continuous, because thicker copper makes the cable heavy and stiff. Liquid cooling removes the heat where it is generated, so the conductors can stay slim and the cable remains easy to handle.
IEC TS 62196-3-1 covers vehicle connectors and cable assemblies with a thermal management system for up to 500 A. The Megawatt Charging System (MCS) for trucks and buses is specified for up to 3,000 A.
Direct and indirect cooling
Two concepts are in use:
- Indirect cooling: the coolant flows in separate channels and is electrically insulated from the conductors. Water-glycol mixtures are common here.
- Direct cooling: the coolant flows along the conductors and contacts themselves. It touches live parts, so it has to be a dielectric fluid – and it becomes part of the insulation system.
Direct cooling takes the heat straight from the copper. In return, the fluid has to meet electrical, thermal and material requirements at the same time.
What the cooling fluid has to do
| Requirement | Why it matters | Typical test |
|---|---|---|
| Electrical insulation | The fluid is in contact with live conductors and contacts and must stay insulating when aged or after taking up moisture | Breakdown voltage (IEC 60156), resistivity and dissipation factor (IEC 60247), water content (IEC 60814) |
| Low viscosity | The fluid is pumped through long, narrow channels to the connector and back; viscosity sets pressure drop and pump power, above all at a cold start | Kinematic viscosity over temperature (ISO 3104) |
| Low-temperature behaviour | Chargers stand outdoors and have to start in winter | Pour point (ISO 3016) |
| Thermal and oxidation stability | Conductors may run at up to 90 °C (IEC TS 62893-4-2); closed systems are expected to work for years without a fluid change | Ageing tests, trend of acid value and viscosity |
| Material compatibility | Copper and plated contacts, cable insulation and jacket, hoses, seals and pump materials are in permanent contact with the fluid | Soak tests with the original materials |
| Fire behaviour | Chargers stand in car parks, depots and at service areas | Flash point and fire point (ISO 2592) |
| Leak behaviour | Charging sites are public and often close to unsealed ground | Biodegradability of the finished fluid (OECD 301) |
Readily biodegradable does not mean harmless – leaked fluid still has to be contained and collected. More on soak tests: material compatibility in immersion cooling.
The viscosity grade is designed for the application
There is no single right viscosity for a cable cooling fluid. Channel cross-sections, cable length, the pump and the lowest start-up temperature decide which viscosity grade works. For cable cooling we develop low-viscosity fluids. IsoTec EC 68 (ISO VG 68) was developed for e-motors and bearings, where the fluid also lubricates – cable cooling calls for a lower viscosity grade, which we design for each application.
Why an ester-based fluid
- Proven as insulating liquids: ester fluids have been used as insulating liquids in transformers for decades and are covered by standards such as IEC 61099 and IEC 62770.
- Moisture tolerance: esters can dissolve far more water than hydrocarbon fluids before the breakdown voltage drops.
- Viscosity range: the viscosity grade can be set through the choice of ester.
- Biodegradability: where it is required, we select readily biodegradable esters and verify the finished fluid by OECD 301 tests.
Developed to your specification
A cable cooling fluid is part of your cable design. We develop it to your requirements – from the first laboratory sample to series supply.
Requirements
You tell us what the fluid has to do: temperature range, viscosity, electrical properties, the materials it touches, standards and volumes.
Laboratory sample
We formulate the fluid for these requirements and supply laboratory samples.
Tests
We test fluid properties and material compatibility in our own laboratory; you test the samples in your system.
Release
The agreed properties are fixed in a specification and data sheet. Trial quantities and series supply follow.
Development, production and sales – including our in-house laboratory – work under a management system certified to ISO 9001:2015 and ISO 14001:2015.
Frequently asked questions
Does a charging cable coolant have to be dielectric?
Where the coolant touches live conductors or contacts, yes. In indirectly cooled designs the coolant is separated from the conductors by insulation, and water-glycol mixtures are common.
Can a transformer ester be used as a cable cooling fluid?
Not without qualification. Transformer fluids are specified for transformers; a cable cooling fluid needs a viscosity grade, low-temperature behaviour and material compatibility that match the cable system. We develop and test the fluid for your design.
Which standards apply to liquid-cooled charging cables?
IEC TS 62196-3-1 covers vehicle connectors, vehicle inlets and cable assemblies with a thermal management system, IEC TS 62893-4-2 the cables and IEC 61851-23 the DC charging station. The fluid itself is tested with methods for insulating liquids, such as IEC 60156 and IEC 60247.
Do you supply samples?
Yes. We supply laboratory samples for your tests and, once the specification is released, trial quantities.
Where does IsoTec supply?
IsoTec products are supplied to customers outside Germany.
Related pages
- IsoTec immersion cooling fluids
- Material compatibility in immersion cooling
- Temperature limits of e-motor cooling fluids
Sources and further reading
- IEC TS 62196-3-1:2020 – Vehicle connector, vehicle inlet and cable assembly for DC charging intended to be used with a thermal management system
- IEC TS 62893-4-2:2021 – Charging cables for electric vehicles: cables for DC charging intended to be used with a thermal management system
- CharIN – Megawatt Charging System (MCS)
- EV Engineering & Infrastructure – Why EV engineers are turning to liquid-cooled charging systems
Developing a liquid-cooled charging cable?
Send us your requirements – we prepare laboratory samples and the test programme. IsoTec products are supplied to customers outside Germany.